The units are microcontroller-based and specially designed to fit all types of LATAB's lighting. This is thanks to a Plug-&-Play function that automatically adapts/limits the current to connected lighting. The lighting is switched on - when an external signal is added to the trigger input - with a pulse length which in the basic model is determined by a rotary switch inside the unit. Three selectable modes of operation; normal/standalone, externally voltage-controlled light intensity and double the current. The product range includes types with up to four lighting outputs/channels as well as control via Ethernet and RS232. Casings of black anodised aluminium.
General specifications | |
---|---|
Supply voltage | 24VDC ± 10%, max. 2,5A x number of channels *1 |
Output power | max. 8 A/ 24A |
Light intensity | Adjustable 0-100% |
Pulsating lighting | Adjustable 50-1500µs i 16 steps |
Trigger input | 5-24V, optically isolated |
Trigger frequency | max. 200 Hz *2 |
Operating temperature | 0-55 °C |
Orderinformation | |||||
---|---|---|---|---|---|
Order number | Intensity control mode | Output power | Number of channels | Trigger delay (0-48 msec) | PDF on request |
PAD1 1131/8 | Intern potentiometer | 8 A | 1 | - | |
PAD1 1131/24 | Intern potentiometer | 24 A | 1 | - | |
PAD1 1141/8 | 0-10V | 8 A | 1 | - | |
PAD1 1231/8 | Intern potentiometer | 8 A/chan. | 2 | - | |
PAD1 1431/8 | Intern potentiometer | 8 A/chan. | 4 | - | |
PAD1 1132/8 | RS-232 | 8 A | 1 | Yes | |
PAD1 1132/24 | RS-232 | 24 A | 1 | Yes | |
PAD1 1432/8 | RS-232 | 8 A/chan. | 4 | Yes | |
PAD1 4132/8 | Ethernet | 8 A | 1 | Yes | |
PAD1 4132/24 | Ethernet | 24 A | 1 | Yes | |
PAD1 4232/8 | Ethernet | 8 A/chan. | 2 | Yes | |
PAD1 4432/8 | Ethernet | 8 A/chan. | 4 | Yes |
*1) The current deflection (average value) depends on the connected lighting and operating conditions such as trigger frequency, set pulse length and light intensity as well as possible synchronization with several channels.
*2) Limitations may occur depending on the control unit and connected lighting.
Cable is ordered separately with article number and cable length. Ex LKA1 1081/3